Indoor Air Chemistry – Creating the “Chemical Soup” of IAQ
(This article originally appeared in the Spring 2004 Issue of Air Media)
Indoor air is a complex mixture of gases and particles. What is not well understood is that many of the things used in indoor environments have the potential to create chemical reactions that can produce totally unintended and potentially harmful results.
Much research has been done recently regarding indoor air chemistry as a source of particles (Weschler, Corsi, Sarwar, Shields, Fick, EPA). As a result of this research, and previous research related to outdoor air, it has been found that ozone (O3) reacts with terpenes and several other volatile organic compounds (VOC’s) to create hydroxyl radicals and numerous small particles. Terpenes are a class of chemicals found as the ‘scent’ in many household products such as cleaners, air fresheners, disinfectants, laundry detergents, furniture wax, etc. For example, the pine scent in many all-purpose cleaners is partially due to pinene. Citrus scents are a result of the presence of limonene. Terpenes are also emitted from natural and manufactured wood products and are generally observed at indoor levels that far exceed outdoor levels (Weschler, Corsi, Sarwar).
Studies of this chemical reaction have found that the substances created by the reaction of ozone and various terpenes include hydroxyl radicals, hydrogen peroxide, formaldehyde, other aldehydes, pinic acid, glyoxal, acetone and numerous other highly oxygenated compounds (Weschler, Shields, Fick, EPA, Yu, Koch) or as the EPA refers to it — a “chemical soup.” There are studies that show many of these products can have adverse effects on the upper airways and the pulmonary regions. (Rohr, Bowler, Kreiss, Jones, Zeliger, American Lung Association, Wolkoff) They can cause skin irritation and produce inflammation. (Matura) Some are probable carcinogens in humans, eg., formaldehyde.
The vast majority of the particles created through the chemical reaction of ozone and terpenes are less than one micron in size, and represent the respirable sizes most likely to reach and be deposited in the alveoli of the lungs (ALA).
In principle all hydrocarbons in the atmosphere will eventually be oxidized and form CO2 and H2O. This process, however, is a complicated and lengthy one especially for complex terpenes. The reaction starts with the oxidation by ozone, NO3 and hydroxyl radicals and includes the formation of particles, radicals and stable products. (Weschler, Fick, Corsi). The hygroscopic secondary organic aerosols resulting from these oxidation reactions may carry other species such as hydrogen peroxide deep into the lower respiratory tract. (Friedlander and Yeh, Weschler)
“Ionizers” have become very popular in recent years and are sold on television, on the radio, by direct mail, over the Internet and in retail stores. The stated features of these devices are quiet operation, no filters to replace, low electricity consumption and “air cleaning ability.” Generally, “ionizers” produce ozone as a byproduct. Would the use of an “ionizer” in a room with common household products create the ozone/terpene reactions and the resulting particles?
For our demonstrations it was assumed that increases in particle counts were from ozone/terpene reactions and other reactions as reported in earlier research studies. Demonstrations were conducted using a particle counter designed to measure all particles over 0.3 microns in size. In a typical indoor environment ambient air has about 1,500,000 particles over 0.3 microns per cubic foot. When an “ionizer” was exposed to various household products such as window cleaning fluid, lemon-scented furniture polish, pine-scented cleaner, baby wipes, baby lotion and baby bath, the particles generated over 0.3 microns exceeded 9,999,999 per cubic foot of air. Many of the compounds and particles created by the ozone/terpene reactions are highly reactive themselves and have a relatively short life. (Weschler) In addition, objects and surfaces in a room such as carpeting, furniture, wall covering, etc. can absorb and adsorb particles.(Weschler) Any overall increase in particles in the room would be the excess created over these factors.
Pine-scented cleaners contain the terpene called pinene as well as other terpenes. We used 100 ml of a pine-scented cleaner in a small bowl to create the terpene source. The two test rooms were 42 square feet (Room 1) and 120 square feet (Room 2) respectively. Particles were measured with a Met One Particle Counter calibrated to measure particles over 0.3 microns per cubic foot. The maximum number that can be recorded with this meter is 9,999,999 per cubic foot.
The ambient air in the rooms before the test had a particle count of 1,250,000 particles over 0.3 microns per cubic foot. Ozone in the rooms was negligible and registered 0.00 parts per million(this would be less than 5 parts per billion) on the ozone meter. The ozone meter we used is only capable of measuring ozone in increments of 10 parts per billion.
We placed an “ionizer” in Room 1 and switched it on. We placed a HEPA Air Purifier in Room 2 and switched it on. After one hour the particle counts were the following:
Room 1 with the “ionizer” — 9,999,999 particles per cubic foot greater than 0.3 microns in diameter (Ozone 20 parts per billion)
Room 2 with the HEPA Air Purifier — 237,000 particles per cubic foot greater than 0.3 microns in diameter (Ozone — negligible)
We then placed the “ionizer” in room 2 and the HEPA Air Purifier in room 1. We did not let the rooms return to the original baseline. We simply switched the machines and turned them on. The initial particle counts in each room approximated the counts recorded in the first phase of the experiment. After 15 minutes we measured the following particle counts.
Room 1 with the HEPA Air Purifier — 290,000 particles per cubic foot greater than 0.3 microns in diameter (ozone 10 parts per billion)
Room 2 with the “ionizer” — 703,000 particles per cubic foot greater than 0.3 microns in diameter (ozone 10 parts per billion)
After 15 more minutes we measured the particle counts.
Room 1 with the HEPA Air Purifier — 79,000 particles per cubic foot greater than 0.3 microns in diameter (Ozone 10 parts per billion)
Room 2 with the “ionizer” — 1,694,000 particles per cubic foot greater than 0.3 microns in diameter (Ozone 20 parts per billion)
Room 3 is 80 square feet. Tile walls. Tile floors.
We placed an “ionizer” (with UV lamp) in Room 3 with 100 ml of pine-scented cleaner. The baseline particle count was 1,560,000 particles per cubic foot greater than 0.3 microns in diameter.
After 30 minutes the particle count was 9,546,000 particles per cubic foot greater than 0.3 microns in diameter.
After an additional 30 minutes the particle count was 9,999,999 particles per cubic foot greater than 0.3 microns in diameter.
We placed an “ionizer” in Room 1. The baseline particle count was 1,560,000 particles per cubic foot greater than 0.3 microns in diameter. We placed 3 baby wipes (Citrus Scent) in the room.
After 30 minutes the particle count was 5,640,000 particles per cubic foot greater than 0.3 microns in diameter.
After an additional 30 minutes the particle count was 3,871,000 particles per cubic foot greater than 0.3 microns in diameter.
Room 4 is a small conference room of 125 square feet. Wood panel walls. Carpeting. One wood conference table and a bookshelf with books in the room.
The baseline particle count in the room was 1,964,000 particles per cubic foot greater than 0.3 microns in diameter. Temperature — 73% F. Humidity — 61%. Ozone in the room before the start of the test — 20 parts per billion.
We first added a bowl of 100ml of pine-scented cleaner to the room. After 15 minutes the particle count in the room was 2,101,000 particles per cubic foot greater than 0.3 microns in diameter. We then turned on the “ionizer” and recorded the particle counts every 15 minutes. After 30 more minutes with the “ionizer” on the particle count over 0.3 microns had risen to 3,815,000 per cubic foot. By 60 minutes after the “ionizer” was turned on the particle count had increased to 7,140,000 and by 75 minutes the particle count of particles and 0.3 microns was maxing out the particle counter at 9,999,999 per cubic foot.
Note: At the termination of the experiment conditions in the room were the following. Temperature -73%. Humidity — 61%. Ozone — less than 20 parts per billion.
After the experiment we turned off the “ionizer” and left the bowl of pine-scented cleaner in the room. Within one hour the particle count was less than 2,000,000 particles per cubic foot greater than 0.3 microns in diameter (1,870,000).
Room 4 — The 4 foot by 6 foot wooden conference table was waxed with lemon-scented furniture polish. We placed an “ionizer” (with UV lamp) in the room and turned it on. The particle counts were the following.
Baseline — 1,560,000 particles per cubic foot greater than 0.3 microns in diameter
After 30 minutes — 3,046,000 particles per cubic foot greater than 0.3 microns in diameter
After 60 minutes — 2,100,000 particles per cubic foot greater than 0.3 microns in diameter
In this case and in the demonstrations using baby wipes, the decrease in particles from the 30 minute reading to the 60 minute reading was likely due to the decrease in the terpene emission rate, and hence terpene levels in the room air over time.
In these demonstrations it was shown that when “ionizers” were exposed to common household products such as cleaners, furniture polish and baby wipes, particle counts in the rooms substantially increased. Particle counts in the test rooms often exceeded the maximum on our meter and registered 9,999,999 particles per cubic foot greater than 0.3 microns in diameter. To put this in some perspective, on a red alert ozone day in a location just 600 feet away from a major highway (with traffic counts of over 270,000 vehicles a day) the highest particle count we have ever recorded is 6,600,000 particles per cubic foot greater than 0.3 microns in diameter.
These particles are highly reactive and are breathed deep into the lungs. Studies have shown that sub-micron particles may have adverse effects on the respiratory system and may cause other health problems.
These demonstrations also illustrate the complexity of indoor air. A “clean, fresh smell” may just be another source of indoor air pollution. The use of “ionizers” and other products such as ozone generators and UV lamps that produce ozone either intentionally or as a by-product has to be questioned. Ozone is a highly reactive compound. As we have seen, it reacts readily with terpenes. It has also been shown to react with other VOC’s (Weschler). It is unknown what types of potentially troubling reactions are taking place with ozone and the multitude of chemicals in something like cigarette smoke. Even in relatively small amounts (less than current FDA standards) ozone can significantly alter the composition of indoor air with unexpected and potentially damaging results.
# # #
Bibliography
Acknowledgements: The authors would like to thank Dr. Charles Weschler (University of Medicine and Dentistry of New Jersey/ Robert Wood Johnson Medical School) and Dr. Richard Corsi (University of Texas) for their insightful comments.
American Lung Association (ALA), 2002. Air Cleaning Devices. State of the Air 2002. (www.lungusa.org)
Boeniger MF. Use of ozone generating devices to improve indoor air quality. Journal of the American Industrial Hygiene Association. 1995, Vol. 56: 590-598
Bowler RP, Crapo JD. Oxidative stress in allergic respiratory diseases. Journal of Allergy and Clinical Immunology. 2002 Sep; 110(3): 349-56
Fick, Jerker; 2003. Chemical Reactions in ventilation systems: Ozonolysis of monoterpenes. Thesis Published by Umea University, Umea, Sweden
Friedlander, S.K.; Yeh, E.K. The Submicron Atmospheric Aerosol as a Carrier of Reactive Chemical Species. Applied Occupational and Environmental Hygiene. 1998, 13, 1-5
Jones, AP. Asthma and Domestic Air Quality. Social Science Medicine. 1998, Vol. 47, 755-764
Koch S, Winterhalter R, Uherek E, Kollof A, Neeb P, Goortgat GK. Formation of new particles in the gas-phase ozonolysis of monterpenes. Atmospheric Environment. 2000. Vol 34, 4031-4042
Kreiss K, Gomaa A, Kullman G, Fedan K, Simoes E, Enright P. Clinical Bronchiolitis Obliterans in Workers at a Microwave Popcorn Plant. New England Journal of Medicine, 2002 Aug; Vol 347:330-338
Li, Ning; Sioutas, Constantinos; Cho, Arthur; Schmitz, Debra; Misra, Chandra; Sempf, Joan; Wang, Meiyang; Oberley, Terry; Froines, John; Nel, Andre. Ultrafine Particulate Pollutants Induce Oxidative Stress and Mitochondrial Damage. Environmental Health Perspectives, April 2003. Vol. 111, Number 4, p. 455-460.
Long CM, Suh HH, Kobzik L, Catalano PJ, Ning YY, Koutrakis P. A Pilot Investigation of the Relative Toxicity of Indoor and Outdoor Fine Particles: In Vitro Effects of Endotoxin and other Particulate Properties. Environmental Health Perspectives. 2001, 109, 1019.
Matura M, Goosens A, Bordalo O, Garcia-Bravo B, Magnusson K, Wrangsjo K, Karlberg AT. Oxidized citrus oil (R-limonene): a frequent skin sensitizer in Europe. Journal of the American Academy of Dermatology. 2002 Nov; 47(5): 709-14
Morrison, Glenn; Corsi, Richard. Smog and Lemons: Discovering Indoor Air Chemistry. EM Magazine, Air and Waste Management Association, May 2003, 14-20.
Rohr, AC; Wilkins, CK; Clausen PA; Hammer M; Nielsen GD; Wolkoff P; Spengler JD. Upper airway and pulmonary effects of oxidation products of (+)-alpha-pinene, d-limonene, and isoprene in BALB/c mice. Inhalation Toxicology 2002 Jul; 14(7):663-84
Rumchev KB; Spickett JT; Bulsara MK, Phillips MR, Stick SM. Domestic exposure to formaldehyde significantly increases the asthma in young children. European Respiratory Journal. 2002 Aug; Vol. 20 (2): 403-408
Sarwar, Golam; Corsi, Richard; Allen, David and Weschler, Charles. 2003 The Significance of Secondary Organic Aerosol Formation and Growth in Buildings: experimental and Computational evidence. Atmospheric Environment, vol. 37 (9-10): 1365-1381
U.S. Environmental Protection Agency, Indoor Environment Management. Ozone Generating Air Cleaners and Indoor Air Chemistry. (www.epa.gov )
Weschler, C. J.; Shields, H. C. Indoor ozone/terpene reactions as a source of indoor particles. Atmos. Environ. 1999, 33, 2301-2312
Weschler, Charles J.; Brauer, Michael; Koutrakis, Petros. 1992a. Indoor Ozone and Nitrogen Dioxide: A Potential Pathway to the Generation of Nitrate Radicals, Dinitrogen Pentaoxide, and Nitric Acid Indoors. Environmental Science and Technology. 26(1): 179-184
Weschler, Charles J.; Hodgson, Alfred T.; and Wooley, John D. 1992b Indoor Chemstry: Ozone, Volatile Organic Compounds and Carpets. Environmental Science and Technology. 26(12): 2371-2377
Weschler, Charles J.; Shields, Helen C. 1996. Production of the Hydroxyl Radical in Indoor Air. Environmental Science and Technology. 30(11): 3250-3268
Weschler, Charles J.; Shields, Helen C. 1997a. Measurements of the Hydroxyl Radical in a Manipulated but Realistic Indoor Environment. Environmental Science and Technology. 31(21): 3719-3722.
Weschler, Charles J.; Shields, Helen C. 1997b. Potential Reactions Among Indoor Pollutants. Atmospheric Environment. 31(21): 3487-3495
Weschler, Charles. Indoor Chemistry as a Source of Particles. Indoor Environment: Airborne Particles and Settled Dust. Morawska L and Salthammer, T, 171-194 VCH-Wiley, Weinheim, Germany, 2003
Wolkoff P; Clausen PA; Wilkins CK; Nielsen GD. Formation of Strong Airway Irritants in Terpene/Ozone Mixtures. Indoor Air; 2000 June, Vol. 10, Issue 2, Page 82.
Yu J, Cocker III DR, Griffin RJ, Flagan RC, Seinfeld JH. Gas-phase ozone oxidation of monoterpenenes: gaseous and particulate products. Journal of Atmospheric Chemistry. 1999, Vol 34, 207-258
Zeliger, HI. Toxic effects of chemical mixtures. Archives of Environmental Health. 2003 Vol 58, 23-29.